# Elegoo Centauri Carbon and Neptune 4 error codes explained

Elegoo Centauri Carbon printers show a numbered error code, such as Error Code 103, while the Neptune 4 series shows Klipper messages in words. This page covers the codes owners hit most on the Centauri Carbon, Centauri Carbon 2 with the CANVAS feeder and Neptune 4, with the meaning and fix from the Elegoo wiki.

Updated Nov 9, 2026. HTML version: https://robotsforthat.com/guides/elegoo-centauri-carbon-error-codes/

## Short answer

As of November 9, 2026, the Elegoo codes that come up most are heating, leveling and filament feed errors. Error 101 means the heated bed did not heat up as expected and 103 means the print head did not. 102 and 104 are bed and nozzle thermistor faults. 502 and 605 are leveling sensor errors, and Elegoo says to start by putting the printer on a flat, steady surface. Codes from 1211 to 1265 on the Centauri Carbon 2 cover the CANVAS feeder: runout, feed, extrusion and unload failures. The Neptune 4 series shows Klipper messages such as MCU shutdown: ADC out of range instead of numbers.

| Code | What it means | What to do |
|---|---|---|
| 101 | Heated bed did not heat up as expected | Power off, check the bed thermistor, bed cables and bed control board |
| 102 | Bed thermistor (NTC) reading fault or disconnected | Reseat the bed thermistor cable on the mainboard |
| 103 | Print head (nozzle) did not heat up as expected | Heat to 200°C and move the head to test the cable; reseat the heater cable |
| 104 | Nozzle thermistor reading fault or disconnected | Reseat the nozzle thermistor cable and check its resistance |
| 205 / 206 | Chamber thermistor disconnected (205) or shorted (206) | Check the chamber thermistor cable on the mainboard |
| 304 | Z axis motor error | Watch Z movement while homing, test the optical limit switch, check the Z motor cable |
| 401 | Accelerometer error during self test or input shaping | Retension the X and Y belts, then rerun the test |
| 502 | Leveling sensor data error; leveling stops | Put the printer on a flat, steady surface, check the locking screws |
| 605 | Pressure (leveling) sensor data error | Remove vibration, check bed tilt and the leveling sensor cables |
| 701 | Mainboard cooling fan fault | Reseat the mainboard fan cable, then home and check |
| 702 | Heat break cooling fan fault | Reseat the heat break fan cable and check the fan spins |
| 703 | Model (part) cooling fan fault | Reseat the model fan cable at both ends |
| 801 | Tool head and mainboard cannot communicate | Power off and reseat the tool head communication cable at both ends |
| 1211 | CANVAS filament ran out | Load filament in the same CANVAS slot and tap Continue |
| 1220 | Unexpected filament found in the tool head; unload by hand | Unload by hand, check the 4 in 1 hub and tool head for a jam, check the detection board |
| 1242 | Filament did not reach the tool head sensor within 30 seconds | Try another CANVAS port to find whether one channel or all four fail |
| 1243 | Extrusion failed at the tool head; may be clogged | Check the hotend type, slicer settings, spool tangles, gear meshing and the hotend |
| 1251 / 1252 | Filament unload failed at the tool head | Look for broken filament in the PTFE tube and 4 in 1 hub; check the detection boards |
| 1263 / 1264 | Extrusion failed: tangled filament, jammed spool or (1264) clogged nozzle | Check that the spool turns freely, find where the filament stops, check the feeder and gearbox |
| 1265 | Tool head did not detect filament; may be jammed | Try other CANVAS ports, check the feeder unit and the detection board |
| heater_bed not heating at expected rate | Neptune 4: bed is not heating fast enough (Klipper) | Check the power supply voltage switch, then the bed and thermistor cables |
| MCU shutdown: ADC out of range | Neptune 4: temperature reading out of range (Klipper) | Power off, reseat the extruder cable, check for bent pins and damaged thermistor wiring |
| mcu THR: Unable to connect | Neptune 4: extruder board not connecting at power on | Check the extruder communication cable for damage and a loose connector or screw |
| Extrude below minimum temp | Neptune 4: nozzle below 170°C when extruding (Klipper) | Print the test file on the USB drive; fix slicer temperatures |

## How Elegoo error codes work

The Centauri Carbon and the Centauri 2 series show errors as Error Code plus a number on the touchscreen. Codes in the 100s are heating and temperature sensors, 300s are motors, 400s to 600s are calibration and leveling sensors, 700s are fans and 800s are communication between boards. The 1200s cover filament and the CANVAS multi color feeder.

The Neptune 4 series runs Klipper, so it shows plain text messages instead, such as Heater heater_bed not heating at expected rate. Search the exact message on the Elegoo wiki to find the matching page.

## Heating and leveling codes

Error 101 means the bed did not heat up as expected. Elegoo lists a cold room, a faulty bed thermistor or heater, and a loose cable to the bed control board. Unplug the printer before you open the bottom cover, because the bed control board carries mains voltage. Error 103 is the same for the print head. Heat to 200°C and move the head by hand. If the error only shows while moving, the extruder communication cable needs replacing.

Error 502 on the Centauri Carbon and 605 on the Centauri 2 series are leveling sensor errors. Elegoo says the printer must sit on a flat, steady surface with all four feet touching, and not on a table with wheels. Then check the locking screws and the sensor cables.

## CANVAS filament codes on the Centauri Carbon 2

The CANVAS is the multi color feeder on Centauri Carbon 2 Combo models. 1211 just means filament ran out; load the same slot and tap Continue. 1242 means filament did not reach the tool head sensor within 30 seconds. Elegoo says to try another CANVAS port first to see whether one channel or all four fail.

1243, 1263 and 1264 are extrusion failures, usually a tangled spool, out of tolerance filament, weak gear meshing or a clogged hotend. 1251 and 1252 are unload failures, often from broken filament in the PTFE tube or the 4 in 1 hub.

## When to contact Elegoo support

Contact Elegoo through its support page if a code stays after the wiki steps. Elegoo says that inspecting the printer as its wiki describes does not affect the warranty. Have the full code, your printer model, the firmware version and the results of each check ready.

## Questions people ask

### What does error 101 mean on the Elegoo Centauri Carbon?

The heated bed did not heat up as expected. Check the bed thermistor, the bed wiring, the bed control board and the power supply, with the printer unplugged.

### What does error 103 mean on an Elegoo printer?

The print head did not heat up as expected. Heat the nozzle to 200°C and move the head by hand. If that triggers the error, replace the extruder communication cable. If not, reseat the heater cable.

### What are the 12xx error codes on the Centauri Carbon 2?

They are filament and CANVAS feeder codes, covering runout, feed, extrusion, unload and detection failures between the CANVAS and the tool head.

### Why does my Neptune 4 show MCU shutdown: ADC out of range?

Elegoo says the extruder cable is usually not seated or has bent pins. Power off, reinstall the cable, wait about a minute and power on.

## Sources

1. [ELEGOO Wiki: Centauri Carbon error messages](https://wiki.elegoo.com/Centauri-carbon)
2. [ELEGOO Wiki: Centauri 2 Series error codes](https://wiki.elegoo.com/centauri-carbon-2-combo)
3. [ELEGOO Wiki: Centauri 2 Series Error Code 1242](https://wiki.elegoo.com/centauri-carbon-2-combo/errorcode-1242)
4. [ELEGOO Wiki: Centauri Carbon Error 502](https://wiki.elegoo.com/Centauri-carbon/leveling-sensor-data-collection-error)
5. [ELEGOO Wiki: Neptune 4/4 Pro MCU shutdown: ADC out of range](https://wiki.elegoo.com/neptune/neptune-4-4-pro-mcu-shutdown-adc-out-of-range)
6. [ELEGOO: Contact support](https://www.elegoo.com/pages/contact-support)